2012年10月29日星期一

High Capacity Heated Desiccant Dryer


Categories: High Capacity Dryers
Brand:KL
Comments:
Large heated desiccant dryer

Heat of compression air dryer is the use of compressed air drying absorber air compressor gas energy conversion when the heat generated by direct heating or hot compressed air to regeneration of the desiccant air drying equipment; no regeneration heater, gas consumption is regenerationless, the greatest degree of conservation of energy.


This equipment adopts PLC automatic control, simple, safe and reliable, renewable gas consumption is small, stable dew point, dew point requirements may be set according to the duty cycle and so on.

High-temperature air from a centrifugal compressor into the first state in the regeneration of adsorber, the adsorbent of the adsorber temperature desorption from the adsorber into the back of the cooler after it is cooled down to room temperature water, after cooling, a large number of compressed airhydrogel formed in the gaseous liquid discharged through the drainage and then into the vapor-liquid separator to further separate the compressed liquid water, greatly reducing the workload adsorber adsorption.And then into the adsorber in the adsorption state of drying, to obtain the dew point of about -40 ℃ dry air.Adsorbent adsorber regeneration state when heated to a certain time, the adsorbent has reached a certain temperature, stop heating, the blowing cold at the same time to switch the system piping, heat the compressed air directly into the back of the cooler is cooled down to room temperature water, the state entered in the regeneration of the cold blow drying adsorber, after blowing cold air after the adsorption state of re-entering the absorber is to dry, and then out of the system.


KeyWords:

2012年10月26日星期五

Water Cooled Water Chiller


Categories: Industrial Water Chiller
Brand:KL
Comments:Water cooled Packaged Chiller(2-300kw)


Detailed Info
Water cooled Packaged Chiller(2-300kw)
1. LSW-series water-cooled chillers are available in sizes ranging from 2 - 200TON. Equipped with pump tanks, high efficiency Scroll compressors, tandem and dual circuit configurations, stainless steel plate evaporator and condensers as well as shell and tube heat exchangers are available, thermostatic expansion valves, filter dryers and sight glasses.
2. Portable chillers are fully packaged and can be converted to a central system. Chillers come packaged with insulated pumps and tanks with level sight glass.
3. Options include: water regulating pressure control, various pump configurations, water makeup, oversized pumps and reservoirs, and potable water isolation heat exchanger systems.

We are a professional Industrial Water Chiller manufacturer and supplier in China. Here you can find high-quality products in a competitive price. Also we supply OEM service of products for you.


KeyWords:



2012年10月24日星期三

Air Pre Cooling Machine


Categories: Air Cooled After Cooler
Brand:KL
Comments:Air Precooling Machine is mainly used in air separation industry.


Detailed Info

Air Precooling Machine is mainly used in air separation industry. Its purpose is to provide user with dried,low-temperature air by cooling commpessed air to eliminate water and lowing its temperature.

In accordance with the characteristic of air separation industry, we developed a new generation of air precooling machine.

Equipped with originally imported key components such as refrigerating compressor, heat expansion valve, hot gas by pass valve,dual pressure switch and electronic drainer etc.

Working Conditions
Work ing Pressure :1.0Mpa

Inlet Tempreture:≤40℃

Outlet Tempreture:5-8℃

Inlet Cooling Water Pressure:0.2-0.4Mpa

Inlet Cooling Water tempreture:≤32℃

Power :380V/3/50HZ/60HZ


Parameter table 
Type ParameterYADL-900YADL-1300YADL-1500YADL-1800YADL-2400YADL-3000YADL-3600YADL-4800YADL-6000YADL-9000YADL-12000YADL-18000
Flow Capacity m3/min9001300150018002400300036004800600090001200018000
Thermal Load KW14.1718.8723.6228.3437.7847.2356.6875.5794.46141.69188.92283.38
Compressor Power KW4.86.37.29.212.616.518.525.53044.556.1675.7
Pipe CoonectionDN50DN80DN80DN80DN100DN100DN125DN150DN150DN200DN200DN250
Cooling Water Consumption m3/h4.45.76.78.110.813.416.221.626.940.453.980.9
Pipe connection of Cooling WaterZG11/2″ZG11/2″ZG11/2″ZG2″ZG2″ZG2″ZG2″ZG21/2″ZG21/2″ZG21/2″ZG3″ZG4″



KeyWords:


Refrigerated Air Dryer


Categories: Air Cooled Dryer
Brand:KL
Comments:ADL -F series Air cooled Refrigerated Air Dryer.



ADL-F Series Refrigerated Air Dryer (Air cooled Normal temperature)

Features
1. Constant dew point temperature
2. Stable performance for long time running
3. External type drain for easy maintenance
4. Low pressure drop for energy saving.
Standard Working Conditions
Air inlet temperature ≤45℃
Ambient Temperature ≤40℃
Working Pressure 2-10 bar
Dew point 2-10℃
Refrigerant R22

Option
1. Environmentally friendly refrigerant, such as R407C and R134a
2. Special power supply
3. NPT connection
4. Dew point indicator
5. High pressure indication for small air dryer
6. Pre filter and after filter installed
7. Higher ambient temperature


KeyWords:


2012年10月22日星期一

High Pressure Air Filter


Categories: Compressed Air Filter
Brand:KL
Comments:KL Compressed Air Filters are used in air system piping and at the point-of-use to protect compress.


Product Description

KL Compressed Air Filters are used in air system piping and at the point-of-use to protect compressed air drying equipment and process machinery and enhance performance. Replaceable elements are available to trap solid particulates, coalesce liquids, or remove aerosols. Filters include many user-friendly advantages including: Push-fit element connection; Durable needle felt outer element layer; Low pressure drop; Restricted height applicability.


Technical data:

Flow capacity: 1.6 to 23 m3/min

Working pressure: 2-40 bar

Class C (3um, 5ppm)

Class T(1um, 1ppm)

Class A(0.01um, 0.01ppm)

Class F(0.01um, 0.001ppm)

Class H(0.01um, 0.003ppm)


KeyWords:



2012年10月21日星期日

Blower Purge Desiccant Dryer


Categories: Blower Purge Desiccant Dryer
Brand:KL
Comments:The blower purge dryer uses a blower instead of a heater to use outside air for the heating element.


Detailed Info
Features:
The blower purge dryer uses a blower instead of a heater to use outside air for the heating element, reducing
operational costs

The use of an auxiliary heater reduces power consumption

An oil-less pneumatic valve ensures precise operation, with speed-adjusting cylinders inside the valves to reduce shock and prevent malfunctions. Cycles can be set to
4hr cycles as well as 8hr and 12 hr cycles

A purge pressure control switch enables easy checking of leaks or valve malfunctions, and a drop in line
pressure shuts down the purged air, ensuring a stable outlet pressure and operational safety

-Further cycle customization possible
Main Technical Data
Working pressure 4 - 10 bar
Dew point ≤ - 40℃
Purge loss 2%/0%
Switch cycle 4 h
Pressure drop ≤0.21bar
Desiccant activated alumina
Inlet oil content 380V/3PH/50HZ
Model & Specifications of KXB-Series Blower Purge Desiccant Dryer

Model
Flow Capacity
Heater
Blower
Connection
Dimensions
Weight
Nm3/min
Kw
Kw
BSP
L x W x H (mm)
Kg
KXB- 200
23
15
3.3
DN65
1560 x 1630 x 2780
1380
KXB-250
27
18
4.2
DN65
1870 x 1830 x 2880
1720
KXB-300
34
24
5.5
DN80
2090 x 1990 x 3070
2060
KXB-400
45
32.4
7.2
DN100
2530 x 2180 x 2920
2750
KXB-500
55
42
8.8
DN100
2750 x 2390 x 3100
3430
KXB-600
65
48
10.8
DN125
2920 x 2510 x 3080
4120
KXB-800
87
64.8
13.8
DN150
3040 x 2780 x 3120
5500
KXB-1000
110
81
17.5
DN150
3210 x 2920 x 3200
6300
KXB-1200
130
95.4
20.8
DN150
3380 x 3080 x 3280
7810
KXB-1500
160
119.7
25.8
DN200
3520 x 3180 x 3410
9200
KXB-2000
210
162
34.5
DN200
3680 x 3320 x 3560
11300
KXB-2500
260
205.2
43.2
DN250
3720 x 3400 x 3640
14000
KXB-3000
320
240
51.8
DN250
3820 x 3480 x 3720
14900
KXB-3500
360
285
59.2
DN300
3950 x 3560 x 3810
16200
KXB-4000
410
318
67.8
DN300
4520 x 3720 x 3890
17900
KXB-5000
510
398
78.2
DN350
5380 x 3980 x 3970
19200


KeyWords:


2012年10月18日星期四

Laser Water Chiller


Categories: Industrial Water Chiller
Brand:KL
Comments:A laser chiller is the main component and the most important device used in managing laser temperature.


Detailed Info
1. A laser chiller is the main component and the most important device used in managing laser temperature to insure high quality performance and long life of the laser system. Laser chillers are completely self-contained devices, able to serve the purpose of removing heat from laser heat-dissipating components. Fluid temperature control is done by microprocessor, which allows it to maintain high temperature accuracy of +/- 0.1 °C for outgoing fluid temperature.
2. Standard features of laser chillers include (but are not limited to):Thermoelectric cooling engine;Reservoir;Liquid pump;Power supply;Temperature controller;Enclosure;Wiring
3.Laser chillers are widely used in such applications as:
Medical (hair, tattoo removal, vein treatment, laser eye surgery, etc.)
Industrial (diode powered Lasers for precise operations)
Any applications where cooling of heat-dissipating components is very important for performance and reliability.

Model
LSW
-02H
-03H
-05H
-08H
-10H
power of compressor
KW
1.84
2.68
4.43
7.00
9.06
HP
2
3
5
8
10
Refrigerating output
Kcal/h
6670
11500
17770
26000
33450
KW
7.76
13.40
20.66
30.20
38.90
refrigerant
R22/R407C/R134a
voltages
3PH/380V/50Hz/60hz
current
A
7
10
16
25
30
power of chilled water pump
KW
0.55
0.75
0.75
1.1
1.5
heating power
KW
6.0
9.0
12.0
18.0
24.0
flow of chilled water
T/h
3
4
4
6
8
connection of chilled water
Inch
1
1-1/2
flow of cooling water
T/h
4
5
8
10
connection of cooling water
Inch
1
1-1/2
dimensions
L
MM
880
880
1200
1500
1500
W
MM
660
660
850
850
900
H
MM
1100
1200
1400
1400
1400
Approx weight
130
140
170
290
380


KeyWords: